产品手册
迅达 300C MMR调试手册
2013-12-01 16:57:23

目录 1 安全 3 2 准备工作...................................................................................................4 3 Mic-SE32A-0110控制板...........................................................................5 3-1 Mic-SE32A-0110控制板概貌..............................................................5 3-2 Mic-SE32A-0110控制板端口说明.......................................................5 4 SM-02-C轿厢板和SM-03-B指令板..........................................................9 4-1 SM-02-C轿厢板和SM-03-B指令板概貌.............................................9 4-2 SM-02-C轿厢板端口说明...................................................................9 4-3 SM-03-B指令板端口说明.................................................................11 4-4 SCOP-SCON-0410轿内显示板概貌………………………………………...11 4-5 SCOP-SCON-0410轿内显示板端口说明……… …………………………12 5 SLOPSCON-0410 厅外显示板............................................................13 5-1 SLOP-SCON-0410 厅外显示板概貌.................................................13 5-2 SLOP-SCON-0410 厅外显示板端口说明..........................................13 6 SMLCD...................................................................................................15 6-1 概述..................................................................................................15 6-2 操作说明...........................................................................................15 7 变频器自学习…………………………………………………………..……… 16 3-1短接线..............................................................................................17 3-2通电..................................................................................................17 3-3设置曳引机参数................................................................................17 3-4确认电机运转方向.............................................................................17 3-5自学习..............................................................................................18 3-6自学习故障以及对策.........................................................................18 8 安装运行.................................................................................................20 8-1机房..................................................................................................20 8-2通电..................................................................................................21 9 快车调试.................................................................................................22 9-1准备工作...........................................................................................22 9-2通电..................................................................................................22 10 电梯舒适感调整......................................................................................25 10-1 电梯载荷控制仪..............................................................................25 10-2 起动力矩补偿..................................................................................27 10-3舒适感整体调整………………………………………………………………….. 29 11 电梯参数表和故障代码表........................................................................29 11-1电梯参数表.....................................................................................29 11-2 电梯参数详细说明...........................................................................33 11-3 电梯故障代码表..............................................................................43 12 变频器参数.............................................................................................46 13 变频器部分代码简述及对策…………………………………………………..49 1 安全 安全要求 安装现场应按安全操作规程要求配置相应的安全防护设备。所有安装人员应按要求 正确使用安全防护设备及设施。 1. 安全设备 1 安全帽 2 防护眼镜 3 安全带 4 防护鞋 5 防护手套 · 在工地和井道安装合适的照明设备。 · 应立即更换或补充被损坏或丢失的安全装备。 · 如果有坠落的风险,应扣好安全带和安全帽。 · 正确使用并妥善保管工具。 · 遵守安装工具及设备制造厂的使用说明。 · 所有安装人员应对自己的安全及健康负责。 2 准备工作 工具与设备 万用表 手持式操作器 WAGO 工具 AMP 工具 一般电工工具 警告 When handling PCBs, always keep to the rules concerning "Handling MOS/CMOS" 文件 装箱清单 电气原理图 土建布置图 3 Mic-SE32A-0110控制板 序号 步骤 备注 3-1 Mic-SE32A-0110控制板概貌 300 3-2 Mic-SE32A-0110控制板端口说明 JP1,JP2,JP3为外部开关信号输入口 l JP1.1 输入X0,检修信号,断开为检修,闭合为自动 l JP1.2 输入X1,上行信号. 在检修时闭合为点动上行,在司机时闭合 为上行换向 l JP1.3 输入X2,下行信号. 在检修时闭合为点动下行,在司机时闭合 为下行换向 l JP1.4 输入X3上行第二终端换速开关, 超过1 /秒以上电梯要求 使用, l JP1.5 输入X4, 下行第二终端换速开关, 超过1 /秒以上电梯要求 使用 l JP1.6 输入X5,上行限位开关 l JP1.7 输入X6,下行限位开关 l JP1.8 输入X7,上行单层终端换速开关. 301 l JP1.9 输入X8,下行单层终端换速开关 序号 步骤 备注 l JP1.10 输入X9,上平层开关 l JP2.1 输入X10,下平层开关 l JP2.2 输入X11,调速器故障输出信号 l JP2.3 输入X12, 火灾返回开关 l JP2.4 输入X13, 第二抱闸开关检测 l JP2.5 输入X14, 备用 l JP2.6 输入X15,调速器进线接触器检测 l JP2.7 输入X16,调速器出线接触器检测 l JP2.8 输入X17,抱闸继电器检测 l JP2.9 输入X18,前门门区开关信号输入,当选择独立门区开关时 用(当有前后门时,建议采用独立门区开关) l JP2.10 输入X19,调速器运行信号检测,检测到此信号闭合则抱闸可 以张开 l JP3.1 输入X20, 再平层或提前开门继电器检测 l JP3.2 输入X21, 消防开关 l JP3.3 输入X22,抱闸开关检测 l JP3.4 输入X23, 曳引马达热保护检测输入 l JP3.5 输入X24,上行第三终端换速开关, 当采用数字量多段速给 定,且电梯速度超过2 /秒以上电梯要求使用 l JP3.6 输入X25,下行第三终端换速开关, 当采用数字量多段速给 定,且电梯速度超过2 /秒以上电梯要求使用 l JP3.7 X0-X25 输入信号公共端 l JP3.8 X0-X25 输入信号公共端 l JP3.9 X0-X25 隔离电路电源负极,0V l JP3.10 X0-X25 隔离电路电源正极,+24V JP12.1-JP12.6 是主机板工作电源 l JP12.1 主控制器工作的0V电源 l JP12.2 主控制器工作的0V电源 l JP12.3 +5V 电源 l JP12.4 主控制器工作的+24V电源 l JP12.5 主控制器工作的0V电源 302 l JP12.6 主控制器工作的0V电源 JP4.1-JP4.4(CAN1) 接外呼板和轿厢板 l JP4.1 外呼和轿厢串行通讯信号端,TXA1- l JP4.2 外呼和轿厢串行通讯信号端,TXA1+ l JP4.3 备用0V输出 303